CellD 40

 

The system includes high efficiency rectifiers, AC and DC connections, battery connection and either Delta PSC 3 or CSU 502 controller.

Download pdf pdf

Email for enquiry

Pre order – email to ca@rectifier.co.za

Categories: ,

Description

CellD systems are small, just like cells. They can be embedded in the telecom infrastructure and are often used in OutD outdoor solutions.

Applications

  • Wireless applications, network base stations, LTE
  • Fixed line applications, broadband services
  • Transmission

Specs

Rectifier module DPR 850B-48 (max. 3 pcs.)
Efficiency 95,2%
Install power (max. config.) 2.55 kW
Input current (per 1 phase) 12 ARMS
Input protection (recom.) 25 A gL/gG type
Height (overall) 43.6 mm (1U)
Width (body) 444 mm (19”)
Depth (overall) 280 mm
Weight 280 mm

DPS 850B-48-3

Max. power 5.1kW
Cabinet:
  • Small Power System (1U), Subrack 19”, H43.6 x W444 x D270 mm, steel
AC-Connection:
  • 1 phase mains connection (1L+N+PE; 230/400V)
DC-Distribution:
  • Max. space for 6x load breakers (2, 4, 6, 10, 16, 20. 25 and 30 A)
  • No breakers are included
Battery connection:
  • 2x battery MCB 50 A (CBI make)
  • Battery Low Voltage Disconnection BLVD
Rectifier shelf:
  • Space and cabling for 3x DPR 850B-48 rectifier modules (Max. power 2.55kW)
Power system controller:
  • ORION ID: B1 power system controller

ORDER OPTIONS

DC load distribution (Choose size and amount of load breaker) / CBI make
  • Load breaker 2 A
  • Load breaker 4 A
  • Load breaker 6 A
  • Load breaker 10 A
  • Load breaker 16 A
  • Load breaker 20 A
  • Load breaker 25 A
  • Load breaker 30 A
System roof (I case of using the DC system inside an optional Wall mounting box or Supporting cabinet maybe not needed)
  • IP20 cover plates
Sliding mounting rails(for easy installation)
  • Sliding rails for CellD40 power system
AC input cables
  • Single phase CABLE 2m (one cable end open)
  • Single phase CABLE 2m (with SCHUKO connector)
External alarm D-sub
  • External alarms are connected from Alarm terminals to ORION/PSC3 controller. Alarm terminals are located on back side of the system.
Battery temp sensor
  • Battery temp sensor 1.5m
  • Battery temp sensor 3m
  • Battery temp sensor 5m
  • Battery temp sensor 10m
  • Adapter for 2 temp sensors
Battery cables
  • Battery cable set 1.5m 10mm2 with cable lugs (M6)
  • Battery cable set 3m 10mm2 with cable lugs (M6)
Packing
  • Packing material (Only needed if not installed in a wall mounting box, supporting cabinet or outdoor cabinet at Delta production)