CellD 125 Evo


The system includes high-efficiency rectifiers, AC and DC connections, battery connection and either ORION or
PSC 3 controller.-3

Download pdf pdf

Email for enquiry
Pre order – email to ca@rectifier.co.za

Description

CellD systems are small, just like cells. They can be embedded in the telecom infrastructure and are often used in OutD outdoor solutions.

Applications

  • Wireless applications, network base stations, LTE
  • Fixed line applications, broadband services
  • Transmission

Specs

Rectifier module DPR 2900B-48

(max. 3 pcs.)

Efficiency 96.4% or  97,2%
Install power (max. config.) 8.7 kW
Dimensions H x W x D 133.5 (3U) x 481.5 (19’) x 329 mm
Weight 15 kg
Input voltage range 80 – 300 VRMS
Max. output current/max. installed power 125 A / 8.7 kW
Controller ORION
Local interface Display, keypad, LEDs
Remote monitoring Alarm relays, modem option, LAN, SNMP protocol

DPS 2900B-48-3

MAX POWER 8.7kW
Cabinet:
  • Small Power System (3U), Subrack 19”, H132 (3U) x W441 (19″) x D359 mm, steel
  • 19″ mounting rails (No sliding rails)
AC-Connection:
  • 3 phase mains connection 3L+N+PE; 230/400V
DC-Distribution:
  • Max. space for 9x load breakers (2, 4, 6, 10, 16, 20. 25, 32, 40, 50, 63A; 1p)
  • 9x MCB alarm card included (Load breaker supervision)
  • No breakers are included
Battery connection:
  • Max. space for 2x  battery breakers (80, 100, 125A; 1p)
  • No breakers are included
  • Battery Low Voltage Disconnection BLVD
Rectifier shelf:
  • Space and cabling for 3x DPR 2900B-48 rectifier modules (Max. power 8.7kW)
Power system controller:
  • ORION power system controller

ORDER OPTIONS

DC load distribution (Choose size and amount of load breaker) / NADER make
  • Load breaker 2 A
  • Load breaker 4 A
  • Load breaker 6 A
  • Load breaker 10 A
  • Load breaker 16 A
  • Load breaker 20 A
  • Load breaker 25 A
  • Load breaker 30 A
  • Load breaker 40 A
  • Load breaker 50 A
  • Load breaker 63 A
Battery breakers (Choose size and amount of breaker) / NADER make
  • Battery breaker 80A
  • Battery breaker 100A
  • Battery breaker 125A
Partial load disconnection (incl. driver board)
  • PLD 150A
System roof (I case of using the DC system inside an optional Wall mounting box or Supporting cabinet maybe not needed)
  • IP20 cover plates
Battery temp sensor
  • Battery temp sensor 3m
  • Battery temp sensor 5m
  • Battery temp sensor 10m
  • TEMP ADAPTER BOARD (2 Temperature sensors)
Battery cables
  • Battery cable set 1.7m 16mm2 M8-SLEEVE/SLEEVE
  • Battery cable set 1.7m 25mm2 M8-SLEEVE/SLEEVE
  • Battery cable set 1.7m 35mm2 M8-SLEEVE/SLEEVE
Packing
  • Packing material (Only needed if not installed in a wall mounting box, supporting cabinet or outdoor cabinet at Delta production)