CellD 300

The system includes high efficiency rectifiers, AC and DC connections, battery connection and either ORION or
PSC 3 controller.

Download pdf pdf

Email for enquiry
Pre order – email to ca@rectifier.co.za

Description

  • This high power density system is ideal for space-critical applications. An integrated modular system allows flexible and adaptable installations.
  • The system includes up to six rectifiers, AC and DC connections, battery connection and Delta PSC 3 controller.
  • Easy installation and expandability add to the success of the system.
  • Delta is known for quality and product reliability, and to this solution has been added cost-effectiveness.

DPS 1600B-48-3

Nominal Power 4,8kW
Cabinet:
  • Small Power System (5U), Subrack 19”, H222 x W444 x D315 mm, steel
  • No Sliding mechanism included
AC-Connection:
  • 3 phase mains connection 3L+N+PE; 230/400V
DC-Distribution:
  • Max. space for 15x load breakers (2, 4, 6, 10, 16, 20. 25, 32, 40, 50, 63A; 1p); 15x MCB alarm card included (Load breaker supervision)
    or
    Max. space for 7x load breakers (80, 100A; 2p)
    or
    Max. space for 5x load breakers (120, 150A; 3p)
  • No breakers are included
Battery connection:
  • Max. space for 6x 80-125A or 3x 160-200A or 2x 250-300A battery breakers
  • No breakers are included
  • Battery Low Voltage Disconnection BLVD
Rectifier shelf:
  • Space and cabling for 3x DPR 1600B-48 rectifier modules (nominal Power 4,8kW)
Power system controller:
  • ORION ID: B1  power system controller

DPS 1600B-48-6

Nominal Power 9,6kW
Cabinet:
  • Small Power System (5U), Subrack 19”, H222 x W444 x D315 mm, steel
  • No Sliding mechanism included
AC-Connection:
  • 3 phase mains connection 3L+N+PE; 230/400V
DC-Distribution:
  • Max. space for 15x load breakers (2, 4, 6, 10, 16, 20. 25, 32, 40, 50, 63A; 1p); 15x MCB alarm card included (Load breaker supervision)
    or
    Max. space for 7x load breakers (80, 100A; 2p)
    or
    Max. space for 5x load breakers (120, 150A; 3p)
  • No breakers are included
Battery connection:
  • Max. space for 6x 80-125A or 3x 160-200A or 2x 250-300A battery breakers
  • No breakers are included
  • Battery Low Voltage Disconnection BLVD
Rectifier shelf:
  • Space and cabling for 6x DPR 1600B-48 rectifier modules (nominal Power 9,6kW)
Power system controller:
  • ORION ID: B1  power system controller

DPS 1600B-48-9

Nominal Power 14,4kW
Cabinet:
  • Small Power System (6U), Subrack 19”, H266 x W444 x D315 mm, steel
  • No Sliding mechanism included
AC-Connection:
  • 3 phase mains connection 3L+N+PE; 230/400V
DC-Distribution:
  • Max. space for 15x load breakers (2, 4, 6, 10, 16, 20. 25, 32, 40, 50, 63A; 1p); 15x MCB alarm card included (Load breaker supervision)
    or
    Max. space for 7x load breakers (80, 100A; 2p)
    or
    Max. space for 5x load breakers (120, 150A; 3p)
  • No breakers are included
Battery connection:
  • Max. space for 6x 80-125A or 3x 160-200A or 2x 250-300A battery breakers
  • No breakers are included
  • Battery Low Voltage Disconnection BLVD
Rectifier shelf:
  • Space and cabling for 9x DPR 1600B-48 rectifier modules (nominal Power 14,4kW)
Power system controller:
  • ORION ID: B1  power system controller

DPS 2400B-48-5

Nominal Power 12,0kW
Cabinet:
  • Small Power System (5U), Subrack 19”, H177x W495 x D315 mm, steel
  • No Sliding mechanism included
AC-Connection:
  • 3 phase mains connection 3L+N+PE; 230/400V
DC-Distribution:
  • Max. space for 18x load breakers (2, 4, 6, 10, 16, 20. 25, 32, 40, 50, 63A; 1p); 18x MCB alarm cards included (Load breaker supervision)
    or
    Max. space for 9x load breakers (80, 100A; 2p)
    or
    Max. space for 6x load breakers (120, 150A; 3p)
  • No breakers are included
Battery connection:
  • Max. space for 6x 80-125A or 3x 160-200A or 2x 250-300A battery breakers
  • No breakers are included
  • Battery Low Voltage Disconnection BLVD
Rectifier shelf:
  • Space and cabling for 5x DPR 2400B-48 rectifier modules(nominal Power 12,0kW)
Power system controller:
  • ORION ID: B1  power system controller

DPS 4000B-48-5

Nominal Power 20,0kW
Cabinet:
  • Small Power System (5U), Subrack 19”, H222x W495 x D315 mm, steel
  • No Sliding mechanism included
AC-Connection:
  • 3 phase mains connection 3L+N+PE; 230/400V
DC-Distribution:
  • Max. space for 18x load breakers (2, 4, 6, 10, 16, 20. 25, 32, 40, 50, 63A; 1p); 18x MCB alarm cards included (Load breaker supervision)
    or
    Max. space for 9x load breakers (80, 100A; 2p)
    or
    Max. space for 6x load breakers (120, 150A; 3p)
  • No breakers are included
Battery connection:
  • Max. space for 6x 80-125A or 3x 160-200A or 2x 250-300A battery breakers
  • No breakers are included
  • Battery Low Voltage Disconnection BLVD
Rectifier shelf:
  • Space and cabling for 5x DPR 4000B-48 rectifier modules(nominal Power 20,0kW)
Power system controller:
  • ORION ID: B1  power system controller

Order Options

DC load distribution (Choose size and amount of load breaker) / GE make 
  • Load breaker 2 A
  • Load breaker 4 A
  • Load breaker 6 A
  • Load breaker 10 A
  • Load breaker 16 A
  • Load breaker 20 A
  • Load breaker 25 A
  • Load breaker 32 A
  • Load breaker 40 A
  • Load breaker 50 A
  • Load breaker 63 A
  • Load breaker 80 A (C50A, 2p)
  • Load breaker 100 A (C63A, 2p)
  • Load breaker 120 A (C50A, 3p)
  • Load breaker 150 A (C63A, 3p)
DC load distribution (Choose size and amount of load breaker) / NADER make 
  • Load breaker 2 A
  • Load breaker 4 A
  • Load breaker 6 A
  • Load breaker 10 A
  • Load breaker 16 A
  • Load breaker 20 A
  • Load breaker 25 A
  • Load breaker 32 A
  • Load breaker 40 A
  • Load breaker 50 A
  • Load breaker 63 A
  • Load breaker 80 A (C50A, 2p)
  • Load breaker 100 A (C63A, 2p)
  • Load breaker 120 A (C50A, 3p)
  • Load breaker 150 A (C63A, 3p)
DC load distribution (Choose size and amount of load breaker) / SCHNEIDER make 
  • Load breaker 2 A
  • Load breaker 4 A
  • Load breaker 6 A
  • Load breaker 10 A
  • Load breaker 16 A
  • Load breaker 20 A
  • Load breaker 25 A
  • Load breaker 32 A
  • Load breaker 40 A
  • Load breaker 50 A
  • Load breaker 63 A
  • Load breaker 80 A (C50A, 2p)
  • Load breaker 100 A (C63A, 2p)
  • Load breaker 120 A (C50A, 3p)
  • Load breaker 150 A (C63A, 3p)
Battery breakers C-curve (Choose size and amount of breaker) / NADER make
  • Battery breaker 80A
  • Battery breaker 100A
  • Battery breaker 125A
  • Battery breaker 150A, incl. Supervision
  • Battery breaker 200A, incl. Supervision
  • Battery breaker 250A, incl. Supervision
  • Battery breaker 300A, incl. Supervision
Battery breakers C-curve (Choose size and amount of breaker) / GE make
  • Battery breaker 80A
  • Battery breaker 100A
  • Battery breaker 125A
  • Battery breaker 150A, incl. Supervision
  • Battery breaker 200A, incl. Supervision
  • Battery breaker 250A, incl. Supervision
  • Battery breaker 300A, incl. Supervision
Battery breakers C-curve (Choose size and amount of breaker) / SCHNEIDER make
  • Battery breaker 80A
  • Battery breaker 100A
  • Battery breaker 125A
  • Battery breaker 150A, incl. Supervision
  • Battery breaker 200A, incl. Supervision
  • Battery breaker 250A, incl. Supervision
  • Battery breaker 300A, incl. Supervision
Battery breakers D-curve (Choose size and amount of breaker) / NADER make
  • Battery breaker 80A
  • Battery breaker 100A
  • Battery breaker 125A
  • Battery breaker 150A, incl. Supervision
  • Battery breaker 200A, incl. Supervision
  • Battery breaker 250A, incl. Supervision
  • Battery breaker 300A, incl. Supervision
Battery breakers D-curve (Choose size and amount of breaker) / GE make
  • Battery breaker 80A
  • Battery breaker 100A
  • Battery breaker 125A
  • Battery breaker 150A, incl. Supervision
  • Battery breaker 200A, incl. Supervision
  • Battery breaker 250A, incl. Supervision
  • Battery breaker 300A, incl. Supervision
Battery breakers D-curve (Choose size and amount of breaker) / SCHNEIDER make
  • Battery breaker 80A
  • Battery breaker 100A
  • Battery breaker 125A
  • Battery breaker 150A, incl. Supervision
  • Battery breaker 200A, incl. Supervision
  • Battery breaker 250A, incl. Supervision
  • Battery breaker 300A, incl. Supervision
Partial load disconnection (incl. driver board)
  • PLD 250A
Sliding rails
  • Sliding rails for CellD300 Evo2 power system
System roof (I case of using the DC system inside an optional Wall mounting box or Supporting cabinet maybe not needed)
  • IP20 cover plates 19IN
Battery temp sensor
  • Battery temp sensor 3m
  • Battery temp sensor 5m
  • Battery temp sensor 10m
  • TEMP ADAPTER BOARD (2 Temperature sensors)
Battery cables
  • Battery cable set 3m 35mm2 with cable lugs (M8)
  • Battery cable set 3m 50mm2 with cable lugs (M8)
  • Battery cable set 3m 95mm2 with cable lugs (M8)
  • Battery cable set 3m 150mm2 with cable lugs (M8)
Packing
  • Packing material (Only needed if not installed in a wall mounting box, supporting cabinet or outdoor cabinet at Delta production)